ULTRA RECON Smoke Odor Seal by Fiberlock (Clear or White & 1 or 5 Gallons): 3092 / 3093

$42.38
(No reviews yet) Write a Review
SKU:
3092-1
Availability:
In Stock! Ships w/in 24 Hours

Description

ULTRA RECON Smoke Odor Sealer is a premium solvent free smoke odor sealant and stain blocker designed to eliminate malodors on multiple surfaces and block tough staining. Ideal for structural, finished and decorative surfaces, ULTRA RECON Smoke Odor Sealer with OdorLock Plus technology is water based and does not contain flammable solvents. 

This multiphase technology provides one coat odor control on most surfaces and continues to block odors even with seasonal changes in temperature and humidity. ULTRA RECON Smoke Odor Sealer is your final step to encapsulate residual odors typically found on fire damage restoration projects.

ULTRA RECON Smoke Odor Sealer is a revolutionary solvent free smoke odor sealant that encapsulates smoke odors on multiple surfaces. ULTRA RECON Smoke Odor Sealer with OdorLock is water based, low VOC, low odor and is not flammable.

  • Permanently encapsulates smoke odors
  • Excellent stainblocker
  • ONE Coat Odor Control
  • Moisture Permeable
  • Blocks Pet & Trauma Scene Odors
  • Water based, non- flammable, low VOC
  • Exceptional application characteristics
  • Bonds to nearly any substrate
  • Easily topcoated, fast drying

Unlike typical water based coatings that “wick” smoke odors and stains out of the substrate as they dry, ULTRA RECON Smoke Odor Sealer with OdorLock Plus technology prevents smoke odors and stains from migrating through the coating, it also contains specialized malodor neutralization technology.

RECON Smoke Odor Sealer is specifically designed to encapsulate malodors on multiple surfaces including:

  • wood,
  • brick,
  • concrete,
  • plaster,
  • sheetrock
  • metal (may require DTM primer)

ULTRA RECON Smoke Odor Sealer is fast drying and has exceptional application characteristics. ULTRA RECON Smoke Odor Sealer is your final step to encapsulate residual odors typically found on fire damage restoration projects.

Coverage

  • Smooth Surfaces: 200-400 sq/ft /gal.
  • Porous Surfaces: 100-200 sq/ft /gal. 

Drying Time

  • To Touch: 30 Min.
  • Recoat: 2 Hours
  • To Topcoat: 2 hours

Surface Preperation

Warning! If you scrape, sand, or remove old paint from any surface, you may release lead dust. LEAD IS TOXIC. EXPOSURE TO LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a NIOSH approved respirator to control lead exposure. Carefully clean up with a wet mop or HEPA vacuum. Before you start, find out how to protect yourself and your family by contacting the U.S. EPA/Lead Information Hotline at 1-800-424- LEAD (5323) or log on to www.epa.gov/lead. Prior to applying Fiberlock’s ULTRA RECON Smoke Odor Sealer (Ultra SOSTM) it is critical that the substrate be thoroughly cleaned. Smoke odor encapsulation is a final step that needs to be part of a comprehensive smoke/odor management protocol.

This protocol should include the following steps:

  1. Odor Cleaning - Fiberlock recommends cleaning with RECON Heavy Duty Cleaner or Extreme Duty Cleaner followed by
  2. Odor Neutralization - application of RECON Extreme Duty Odor Counteractant followed by
  3. Odor Encapsulation. - After the substrate is clean, dry and sound, apply ULTRA RECON Smoke Odor Sealer to encapsulate any residual odors that remain. 

Application

Apply ULTRA RECON Smoke Odor Sealer generously and uniformly by brush, airless spray or roller. Apply one coat of ULTRA RECON Smoke Odor Sealer and ensure that the finished surface is properly sealed. Two-coats may be required on some porous or heavily stained surfaces. Topcoat floor applications when foot traffic or heavy storage is expected. ULTRA RECON Smoke Odor Sealer is tintable up to 2 oz. of universal liquid colorant per gallon. Can be directly applied to wallboard, sheetrock, wood, masonry and concrete. Ferrous metals may require a DTM primer to prevent flash rusting. 

Cleanup

Clean tools and drippings with warm soapy water before ULTRA RECON Smoke Odor Sealer dries. Dispose of waste according to all existing local, state and federal regulations. 

Precautions

Store in a dry place at temperatures between 40°F (4.5°C) and 90°F. (32°C). Stir thoroughly. Do not mix with any other coatings, additives, solvents or colors in oil. Do not apply when air or surface temperature is below 45°F, or when drying conditions are poor or when surfaces are above a 15% moisture level content. In areas with high humidity, apply when surface temperature is 45°F or higher. Use adequate ventilation during application. When applying with a sprayer, wear a NIOSH approved respirator with any R, P, N or HE filter. 

Properties

Product Specifications

  • Solids by Weight ± 2%:                48.3%
  • Solids by Volume ± 2%:               46.2%
  • Viscosity at 70°F:              
    • White:                   94 Kreb Units
    • Clear:                    85 Kreb Units
  • Specular Gloss:                  3º ± 5 @ 60º
  • Flash Point:                    Non-combustible
  • Shelf Life:                        24 Months Min. 
  • Calculated VOC:
    • White:                   49 grams/liter
    • Clear:                    69 grams/liter

Product Testing

  • Water Vapor Permeance:
    • ASTM E96B - Dry Cup @ 3 dry film thickness: 1.673 perms